Product Introduction
The HM-BDX is a portable biological toxicity analyzer that integrates two complementary detection methods: quantitative bioluminescent bacteria toxicity measurement and qualitative chemiluminescence-based toxicity screening. Using bioluminescent bacteria as biosensors, the instrument quantifies toxicity by measuring the inhibition of bacterial luminescence, while the chemiluminescence method employs horseradish peroxidase-catalyzed luminescence to detect toxicity through enzyme activity inhibition. This dual-method approach provides a comprehensive toxicity profile for water and environmental samples.
Equipped with a 7-inch touchscreen display and an auto-elevating detection dark chamber, the HM-BDX streamlines the testing workflow from sample preparation to result output within 15 minutes. Results are presented in multiple formats — quantitative concentration (mg/L), qualitative toxicity grade (low/moderate/high/severe/acute toxicity), and luminescence inhibition rate (%) — enabling operators to quickly interpret toxicity levels. The instrument features RJ45, WiFi, 4G, and Bluetooth connectivity along with a built-in 6000mAh lithium battery providing over 8 hours of continuous operation, a thermal printer for on-site documentation, and cloud-based data management platform for remote monitoring and analysis.
Applications
Municipal wastewater treatment: toxicity monitoring of influent and effluent for regulatory compliance
Industrial discharge monitoring: quantitative assessment of toxic pollutant levels in factory wastewater
Drinking water source protection: early warning screening for acute toxicity in reservoirs and intake points
Environmental water quality assessment: surface water and groundwater toxicity evaluation across watersheds
Emergency pollution incident investigation: rapid on-site toxicity identification and grading for spill response
Scientific research: toxicity evaluation of new chemicals, pharmaceuticals, and environmental samples in laboratory studies
Functional Performance / Features
7-inch color touchscreen for intuitive parameter setting and real-time data visualization
Dual detection methods: quantitative bioluminescent bacteria method and qualitative chemiluminescence method
Auto-elevating detection dark chamber for consistent measurement conditions and operational convenience
Multi-format result output: quantitative (mg/L), qualitative (5-level toxicity grade), and inhibition rate (%)
15-minute sample-to-result workflow for rapid toxicity assessment
Measurement range: 0 to 1×10⁷ mV with spectral range of 340 to 1000 nm
Clean water luminescence inhibition rate accuracy: ≤±5%
Repeatability: relative deviation of 3 measurements less than 1%
Zn²⁺ relative linear error: ≤±10%
Comprehensive connectivity: RJ45, WiFi, 4G, and Bluetooth for data transmission and remote access
Built-in 6000mAh lithium battery with over 8 hours continuous operation
Thermal printer for immediate on-site result documentation
Main Parameters
| Parameter | Specification |
|---|---|
| Detection Mode | Bioluminescent bacteria (quantitative) + Chemiluminescence (qualitative) |
| Detector | Silicon photomultiplier (SiPM) |
| Dark Chamber | Auto-elevating detection dark chamber |
| Display | 7-inch touchscreen |
| Measurement Range | 0 ~ 1×10⁷ mV |
| Spectral Range | 340 ~ 1000 nm |
| Inhibition Rate Range | -100% ~ 100% |
| Clean Water Inhibition Rate Accuracy | ≤±5% |
| Repeatability (3 measurements) | Relative deviation < 1% |
| Zn²⁺ Relative Linear Error | ≤±10% |
| Test Time | 15 minutes after sample preparation |
| Result Display | Quantitative (mg/L) / Qualitative (5-level) / Inhibition rate (%) |
| Battery | 6000mAh lithium battery, 8h+ endurance |
| Compliant Standards | GB/T 15441-1995, ISO 11348-3, JJF 2203-2025 |
Technical Parameters
| Parameter | Specification |
|---|---|
| Product Model | HM-BDX |
| Product Type | Portable biological toxicity analyzer |
| Detection Principle | Bioluminescent bacteria metabolism inhibition + HRP-catalyzed chemiluminescence |
| Toxicity Detection Mode | Quantitative (bioluminescent bacteria) + Qualitative (chemiluminescence) |
| Detector Type | Silicon photomultiplier (SiPM) |
| Dark Chamber | Auto-elevating detection dark chamber |
| Display | 7-inch color touchscreen |
| Measurement Range | 0 ~ 1×10⁷ mV |
| Spectral Range | 340 ~ 1000 nm |
| Inhibition Rate Range | -100% ~ 100% |
| Clean Water Inhibition Rate | ≤±5% |
| Repeatability | 3 measurements relative deviation < 1% |
| Sensitivity | Equivalent or superior to fish 96h culture method |
| Zn²⁺ Relative Linear Error | ≤±10% |
| Test Time | 15 min after sample preparation |
| Result Display | mg/L / Low-Moderate-High-Severe-Acute / % |
| Connectivity | RJ45, WiFi, 4G, Bluetooth |
| Battery | Built-in 6000mAh, 8h+ endurance |
| Printer | Thermal printer |
| Data Management | Cloud data management platform |
| Optional | BeiDou satellite positioning |
| Applicable Standards | GB/T 15441-1995, ISO 11348-3, JJF 2203-2025 |
Current
Location:
+86 17853698681
WhatsApp
Product Details
Related Products