HM-CWF4 Bacterial growth concentration detector
1. ※ Light source flicker algorithm, compared to traditional detection methods, increases the service life of the light source. Extending the lifespan of the light source, reducing the intensity of light stimulation, allowing for faster detection and less degradation of the tested product
2. Light source fluctuation pp value (* high intensity decrease * low intensity)<0.5%
3. Using unique motor control technology and adopting four optical path detection method, stability, repeatability, linearity are more stable, and the detection range is larger
4. ※ The sample does not need to be diluted, and the concentration range of the measurable sample is more than 150 times that of a conventional UV visible spectrophotometer
5. Equipped with OD600 optical path detection system, colorimetric dish mode, convenient for detecting the concentration of bacteria, microorganisms, and other culture media
6. Fluorescence detection, combined with a fluorescence quantitative analysis kit, quantifies DNA, RNA, and protein concentrations through specific binding between fluorescent dyes and target substances, with a low limit of up to 0.5pg/ul (dsDNA)
7. Deeply customized Android operating system, 7-inch capacitive touch screen, no need for computer connection, can be detected on a single machine
8. ※ With a simple and easy-to-use data to printer option, you can directly print reports through the built-in printer
9. Adopting image and table storage formats, the table is compatible with Excel, facilitating subsequent data processing, and supports JPG image export
10. Wavelength range 190-850nm
11. Sample volume requirement: 0.5-2ul
12. ※ Optical path 0.03mm, 0.05mm (high concentration measurement) 0.2mm, 1.0mm (normal concentration measurement)
13. Light source xenon flash lamp
14. Detector HAMAMATSU UV Enhanced CMOS Linear Array Sensor
15. absorbance * * degree 0.003Abs (0.2mm optical path)
16. Accuracy of absorbance ± 1% (7.332Abs at 260nm)
17. Absorbance range (equivalent to 10mm) 0.04-300A
18. Nucleic acid testing range 2-15000ng/ μ L (dsDNA)
19. Detection time<6S
20. Data output method USB
21. Sample base material: Quartz fiber optic and high hardness aluminum
22. Power adapter 24V DC
23. Power consumption 25W
24. Power consumption in standby mode: 5W
25. Size (W x D x H) mm 200 x 260 x 165
26. Weight (KG) 5KG
27. Software operating platform Android system
- Previous: Ultraviolet visible ultra trace spectrophotometer