Volatile basic nitrogen detection instrument

Volatile basic nitrogen detection instrument

Product Number:

HM-YJ12

Product Difference:

Accuracy error: ± 3% Linear error: ± 5 ‰ Stability: ± 0.001 A/hr

/skin/Product Details

Product Usage:

The volatile salt based nitrogen detection instrument is an integrated and fast food safety detection and analysis equipment, widely used in food and drug supervision bureaus, health departments, higher education institutions, research institutes, agricultural departments, breeding farms, slaughterhouses, food and meat product deep processing enterprises, inspection and quarantine departments and other units.

Testing items:

It can quickly detect volatile basic nitrogen in diseased meat, and the instrument reserves other detection programs and ports. It can conveniently increase detection items according to future needs.

[Applicable samples]

Pork, beef, lamb, fish, etc

Function introduction:

1. The Android intelligent operating system adopts more efficient and user-friendly operation, and the instrument has network cable connection, WiFi networking upload, GPRS wireless remote transmission function, and can quickly upload data.

2. High level of intelligence, the instrument has self checking function: it has startup self checking and zero adjustment functions, and automatic detection of repeatability.

3. Detection channels: ≥ 12 detection channels, capable of testing multiple samples simultaneously. Each sample is controlled by the program to work independently without interfering with each other.

4. Display method: ≥ 8-inch LCD touch screen display, user-friendly Chinese operation interface, intuitive and simple reading.

5. Equipped with a new generation embedded thermal printer, it can be manually printed or automatically printed. After the detection is completed, the detection report and QR code can be automatically printed.

6. The light source adopts imported ultra-high brightness light-emitting diodes, which have high precision, strong stability, controllable light source, and can turn off unused light sources, resulting in lower power consumption.

7. Adopting USB2.0 interface design, it facilitates data storage and movement, and can be directly connected to a computer at any time, and can be used to control instruments. Implement data queries, browsing, analysis, statistics, printing, and more.

8. The instrument comes with a regulatory platform. The data can be uploaded via LAN and Internet, and the test results can be directly transmitted to the food safety supervision platform. Conduct regional food safety supervision and big data analysis and processing, detect the long-term and short-term dynamics of regional food safety, and achieve food safety problem estimation and early warning

9. The instrument has a menu library of multiple types of samples, allowing for flexible selection of detection samples. Different detection channels can simultaneously detect different sample items.

10. The sample processing is simple and labor-saving, and the overall operation is fast, safe, and convenient.

11. The instrument has its own protection function, which can be set with a username and password to prevent non staff operations.

12. High sensitivity, high detection accuracy, high repeatability accuracy, scanning type high-precision optical sensor.

13. Equipped with a powerful database, you can directly select information such as sample name, testing indicators, and testing unit on the instrument. You can also directly edit and input information such as sample name, testing indicators, and testing unit on the instrument and save it in the sample database.

14. The instrument has functions of recalibration, locking, and factory reset.

15. Supports USB storage. The result judgment line can be modified, the calibration value of the reference value can be saved, and data will not be lost when power is turned off.

Main parameters:

1. The main control chip adopts ARM Cortex-A7, RK3288/4 core processor, with a main frequency of 1.88GHz, which runs faster and has stronger stability.

2. DC 12V power supply, can be connected to car power supply, can be equipped with a 6Ah large capacity rechargeable lithium battery, convenient for outdoor flow testing.

3. Dual wavelength cold light source, each channel is equipped with a 405nm and 520nm wavelength light source, equipped with advanced optical path switching device as standard. The patented optical path switching function can achieve * 64 wavelengths, and all detection items can achieve simultaneous detection of all channels.

4. Automatic adjustment and calibration of light source brightness

5. Intelligent constant current voltage regulation, automatic calibration of light intensity, and long-term continuous operation of the light source without temperature drift phenomenon.

6. Continuous injection and detection

7. Sample numbers are automatically accumulated.

8. The detection items can be expanded.

9. The detection results can be printed and uploaded in batches.

10. The test results are in an Excel spreadsheet, which can be copied by connecting to a computer.

11. Storage capacity of 200000 test results

12. Standard USB interface, driver free installation.

13. Can be configured with large capacity lithium batteries, firmware can be upgraded

Technical parameters:

☆ Accuracy error: ± 3%

☆ Linear error: ± 5 ‰

☆ Stability: ± 0.001 A/hr

☆ Wavelength accuracy:<2.0nm

☆ Wavelength range: 450nm

☆ Wavelength range: 410nm

☆ Wavelength range: 480nm

☆ Freshness: detection lower limit 20mg/kg, linear range 0-1000mg/kg

☆ Volatile base nitrogen: Lower detection limit: 10mg/kg Linear range: 0-300mg/kg

☆ Transmission specific gravity reproducibility: ± 1%

☆ Data storage of 80,00 pieces

☆ Color comparison vessel: 10 × 10mm standard sample cell

☆ Appearance size: 400x300X180 (mm)

[Compliant with standards]

According to GB2707-2005 "Hygienic Standards for Fresh (Frozen) Animal Meat", the TVB-N of fresh and frozen animal products should be ≤ 15mg/100g,

GB16869-2005 "Hygienic Standards for Fresh (Frozen) Poultry Meat" stipulates that the TVB-N of fresh and frozen poultry products should be ≤ 15mg/100g,

GB2733-2005 "Hygienic Standards for Fresh (Frozen) Animal Aquatic Products" stipulates that TVB-N in marine fish, shrimp, and cephalopods should be ≤ 30mg/100g, and TVB-N in freshwater fish and shrimp should be ≤ 20mg/100g