Search icon
×
Positioning iconCurrent Location:Home>BLOG>HENG MEI Intelligent Manufacturing Multiparameter Water Analyzers and Test Menus

HENG MEI Intelligent Manufacturing Multiparameter Water Analyzers and Test Menus

Article Source: Hengmei Technology    Release time:2026-11-13 13:32:32

HM-B100 Multiparameter Water Quality Analyzer on a white background

Select a multiparameter water analyzer by the actual parameter menu, sample matrix and preparation methods. HM-B100 combines photometric measurement with a dual-temperature-zone digestion module in a carrying case. Build the configured menu around the water-quality questions that need to be answered.

HM-B100 is part of the HENG MEI Intelligent Manufacturing range supplied by Shandong Hengmei Electronic Technology Co., Ltd.

How the measurement works

HM-B100 combines tube and cuvette photometry with an eight-position, dual-temperature-zone digestion module. COD, ammonia nitrogen, total phosphorus and total nitrogen each use their corresponding chemistry, range and preparation conditions within the configured water-test menu.

Specify a usable parameter menu

Prepare a list of parameters, concentration ranges and water matrices. Identify which methods need digestion, which need other reaction conditions and which consumables each uses. Allocate positions for blanks and controls. Compare the complete method configuration, including reagents, cooling arrangements and sample handling, against the intended workload.

Technical configuration

ParameterSpecification
Display8-inch touchscreen
Digestion module8 positions with two independently controlled zones
Measurement formats16 mm tubes and compatible cuvettes

Review dilution and batch allocation

A 1 mL water portion diluted to 10 mL has a dilution factor of ten. A method result of 4 mg/L on that diluted sample corresponds to 40 mg/L in the original sample. If an eight-position digestion batch reserves two positions for controls, six positions remain for sample preparations under that layout.

Interpret each parameter through its method

Keep the parameter name, unit, reaction program and dilution factor with every result. Total and dissolved measurements can require different sample treatment, so label the selected fraction. Compare results with the applicable limit using the same analytical quantity and units. Review control acceptance before releasing a batch.

Compare several water parameters from one sampling event

When one sampling event supplies several tests, plan the containers, preservation and preparation separately for each requested parameter. Record which portion is used for each method and retain the collection identity through dilution and digestion. Group compatible preparation stages while preserving the reaction conditions required by each test. Review blanks and controls before combining the results into a water-quality report. Trends become easier to interpret when the parameter name, analytical fraction and unit are consistent between visits. The multiparameter system provides a common measurement platform within these distinct analytical pathways.

Put the selected method into practice

  1. Identify each sample and select the target parameter and method.
  2. Prepare the required blank, calibration or control materials.
  3. Carry out digestion or color development where specified, then measure in the correct format.
  4. Apply the recorded dilution factor and review quality-control results before reporting.

Plan support for common operating issues

Operating issueChecks and follow-up
One parameter gives unusual resultsReview that parameter’s reagents, preparation and program rather than changing all methods.
Digestion results varyCheck loading, program, reaction completion and cooling procedure.
High-concentration samples exceed rangeUse the permitted dilution and retain the original-sample factor.

Plan the complete working configuration

List the required parameters, concentration ranges and sample matrices first. Separate tests needing digestion from those with other reaction procedures, and estimate batch capacity with the required blanks and standards included. Compare reagent availability, cooling and handling arrangements, power needs and record export. An extensive menu is valuable when its methods fit the laboratory workload.

Define the acceptance and reporting requirements

Agree on the following items when configuring HM-B100. They connect the equipment and consumables to the intended measurement and provide a basis for operator training and result review.

  • Water source and sample identity
  • Parameter, fraction and method
  • Digestion or reaction settings
  • Dilution, calibration and controls

Questions from buyers and laboratory teams

Does every listed parameter need digestion?

Use the parameter-specific method to determine the preparation and reaction steps.

What limits batch capacity?

Include digestion positions, controls, reaction time, cooling and measurement availability in the schedule.

For a HM-B100 configuration enquiry, provide the sample type, required measurements, expected workload and reporting requirements. Include the consumables, preparation equipment and support arrangements needed at the installation site.


Address of this article:https://www.kjhm.net/news/multiparameter-water-analyzers-and-test-menus.html