Product Introduction
The HM-D1 Automatic Potentiometric Titrator is a precision analytical instrument designed for laboratories that require reliable, automated titration without the complexity of multi-module configurations. Built on a modular hardware platform, the HM-D1 supports the four fundamental titration methods — acid-base, redox, precipitation, and complexometric titration — covering the majority of routine volumetric analysis tasks.
Powered by an Android 10 operating system with a 7-inch capacitive touchscreen, the instrument offers an intuitive graphical interface that reduces the learning curve for new users. Its high-precision fluid control system achieves titration repeatability of ≤0.2%, ensuring consistent results across repeated runs. The dual titration mode — conventional and specialized — allows users to either customize parameters freely or run pre-configured standard methods with one-click operation.
With 100,000-record local storage, PDF and Excel export, built-in thermal printing, and Wi-Fi connectivity, the HM-D1 integrates seamlessly into modern laboratory workflows. For labs seeking an affordable entry point into automated potentiometric titration, the HM-D1 provides proven performance with straightforward operation.
Applications
Food Safety: Determination of acid value, peroxide value in edible oils; amino acid nitrogen in soy sauce and vinegar; acidity and alkalinity in various food products
Environmental Monitoring: Water quality analysis including COD, chloride ions, and ammonia nitrogen determination
Pharmaceutical & Cosmetics: Raw material content assay, solution pH monitoring, and cleaning validation
Petrochemical: Analysis of acid value, base value, and sulfur content in oil products; purity testing of chemical raw materials
Education & Research: Chemistry teaching experiments and fundamental titration research in universities and research institutes
Features
Four Core Titration Methods: Supports acid-base, redox, precipitation, and complexometric titration in a single instrument, covering most routine analysis needs.
Android 10 Smart Platform: 7-inch HD capacitive touchscreen with intuitive graphical UI for straightforward method setup and real-time curve monitoring.
High Repeatability: Titration analysis repeatability ≤0.2% with endpoint accuracy, delivering reliable and reproducible results.
Integrated Fluid System: Valve-burette integrated design supporting quick 10 mL / 20 mL burette replacement; corrosion-resistant tubing for acids, alkalis, and organic solvents.
Dual Titration Mode: Conventional mode for flexible parameter customization; Specialized mode for one-click standard method execution with direct result output.
Multiple Endpoint Detection: Dynamic, equal-volume, preset endpoint, and manual titration modes with automatic curve inflection point identification.
Method & Data Management: Create, edit, store, and recall titration methods; built-in substance library and custom calculation formulas; 100,000-record local storage.
Data Integrity: Three-level user permission management with complete audit trail, compliant with GLP/GMP laboratory quality standards.
Convenient Data Output: Dual-format export (PDF & Excel), built-in thermal printer, Wi-Fi upload to LIMS, USB and Ethernet interfaces.
System Reliability: Power-off protection prevents data loss; system self-diagnosis and alarm settings; software upgradeable via USB or network.
Main Parameters
| Parameter | Value |
|---|---|
| Titration Analysis Repeatability | ≤ 0.2% |
| Titration Analysis Error | ≤ ±1.5% |
| 10 mL Burette Accuracy | ±5 μL |
| 20 mL Burette Accuracy | ±10 μL |
| Potential Range | -2,000 mV ~ +2,000 mV |
| Potential Resolution | 0.1 mV |
| pH Range | 0 ~ 14 pH |
| pH Resolution | 0.01 pH |
| Temperature Range | -5 ~ 105 °C |
| Temperature Resolution | 0.1 °C |
Technical Parameters
| Category | Parameter | Value |
|---|---|---|
| Titration Performance | Repeatability | ≤ 0.2% |
| Analysis Error | ≤ ±1.5% | |
| 10 mL Burette Error | 10 μL / 10 mL | |
| 20 mL Burette Error | 20 μL / 10 mL | |
| Potential Measurement | Range | -2,000 mV ~ +2,000 mV |
| Resolution | 0.1 mV | |
| Basic Error | ±0.25‰ FS | |
| Stability | ±0.3 mV / 3 h | |
| pH Measurement | Range | 0 ~ 14 pH |
| Resolution | 0.01 pH | |
| Basic Error | ±0.01 pH | |
| Temperature | Range | -5 ~ 105 °C |
| Resolution | 0.1 °C | |
| Basic Error | ±0.2 °C | |
| System Specifications | Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen | |
| Data Storage | 100,000 records | |
| Data Interface | USB, Wi-Fi, Ethernet | |
| Data Export | PDF, Excel | |
| Printer | Built-in thermal printer | |
| Power Supply | AC 110~240V, 50~60 Hz | |
| Dimensions / Weight | 310×226×233 mm / ~3.7 kg |
Reference Standards
JJG 814-2015 Verification Regulation for Automatic Potentiometric Titrators
GB/T 29252-2012 Quality Inspection Rules for Laboratory Instruments
GB 4793.1-2007 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use