Search icon
×
Positioning iconCurrent Location:Home>PRODUCTS>Laboratory Instrument>Flame Meter>HM-FP5 Flame Photometer
HM-FP5 Flame Photometer

HM-FP5 Flame Photometer

Product Number:

HM-FP5

Product Difference:

The HM-FP5 is the flagship model with five simultaneous detection channels for potassium, sodium, lithium, calcium, and barium — providing the complete alkali and alkaline earth metal profile in a single flame photometric run, designed for professional laboratories requiring comprehensive multi-element analysis with full data traceability.

/skin/Product Details

HM-FP5 flame photometer complete unit with 7-inch touchscreen control module and sample introduction system

HM-FP5 flame photometer six core advantages including touch screen multi-element detection and one-touch ignition

HM-FP5 flame photometer applications across environmental monitoring agriculture food industry and chemical manufacturing

HM-FP5 flame photometer atomic emission spectroscopy detection principle with five-step process diagram

HM-FP5 flame photometer 7-inch color capacitive touch LCD with intuitive menu interface and function grid

HM-FP5 flame photometer multi-element detection showing element concentration direct reading capability

HM-FP5 flame photometer one-touch ignition system with built-in air pump and high-performance nebulizer

HM-FP5 flame photometer data management with calibration curve storage thermal printing and USB export functions

HM-FP5 flame photometer safety features with flame-out protection moisture separator and stability metrics

HM-FP5 flame photometer complete technical specifications table with all operating parameters

HM-FP5 flame photometer compliance standards list including JJG630 and soil plant analysis methods

HM Instruments Shandong Hengmei Electronic Technology company manufacturing facility and laboratory overview

Product Introduction

The HM-FP5 Flame Photometer is the flagship five-channel atomic emission spectrometer from HM Instruments, engineered for professional laboratories that demand the complete alkali and alkaline earth metal profile — potassium, sodium, lithium, calcium, and barium — from a single aspiration. Each of the five independent channels uses a dedicated high-transmittance interference filter paired with a silicon photocell detector, delivering direct concentration readout for all target elements without cross-interference or sequential re-measurement.

The instrument's 7-inch color capacitive touch LCD consolidates all control functions into an intuitive interface, while the built-in thermal printer and USB drive export provide dual-path data documentation for quality management and regulatory compliance. Up to 10 calibration points per element and 20 stored curves accommodate diverse sample matrices, with segmented, linear, and curve fitting modes supporting both routine quality control and research-grade method development.

A self-developed high-performance nebulizer maintains sample aspiration below 6 mL/min, and one-touch ignition with a built-in air pump eliminates external compressor dependency. Flame-out protection with automatic gas valve shutoff and a moisture separator for environmental stability ensure reliable, safe operation in demanding laboratory conditions. The HM-FP5 meets JJG630-2007 verification requirements and is the definitive choice for laboratories needing comprehensive five-element flame photometric analysis.

Applications

  • Research-grade geological and mineralogical analysis — complete alkali metal profiling in rock, ore, and sediment samples
  • Petrochemical laboratory testing — sodium and potassium catalyst residue monitoring in refined products
  • Pharmaceutical quality control — lithium content verification in drug substance and raw material batches
  • Advanced soil science research — simultaneous K, Na, Li, Ca, Ba determination for soil mineralogy studies
  • Ceramic and glass raw material analysis — alkali and alkaline earth metal content in feldspar, clay, and glaze formulations
  • Clinical and forensic toxicology — barium and lithium screening in biological specimens
  • Environmental compliance monitoring — multi-element alkali metal discharge tracking in industrial wastewater

Functional Performance

  1. 7-inch color capacitive touch LCD provides a compact, stable, and reliable operating platform with clear visual feedback for all instrument functions
  2. Five simultaneous detection channels for K, Na, Li, Ca, Ba — the complete alkali and alkaline earth metal suite in one flame photometric run
  3. High-transmittance, ultra-low stray-light interference filters ensure clean spectral isolation for each of the five element channels
  4. One-touch ignition with built-in air pump simplifies daily startup and eliminates external compressor requirements
  5. Self-developed high-performance nebulizer delivers stable, reproducible aspiration below 6 mL/min for minimal sample consumption
  6. Up to 10-point calibration curves per element, 20 curves stored, supporting segmented, linear, and curve fitting methods
  7. Moisture separator shields optical and electronic components from humidity-induced signal drift in challenging environments
  8. Flame-out protection with automatic gas valve shutoff prevents unburned gas release during unattended operation
  9. Single-point calibration corrects baseline drift between full recalibration cycles, reducing standard solution usage and downtime
  10. Historical record printing via built-in thermal printer and USB drive export for complete data traceability and audit compliance

Main Parameters

ParameterValue
Product ModelHM-FP5
Test ElementsNa, K, Li, Ca, Ba (5 channels)
Operation Method7-inch color capacitive touch LCD
Spectral MethodInterference filter
Photoelectric ElementSilicon photocell
Concentration CalculationSegmented method, linear fitting, curve fitting
Calibration Curve StorageUp to 10 points per curve, 20 curves total
Stability≤3% (15s), ≤8% (6 measurements)
Repeatability≤2%
Response Time<8s
Sample Aspiration Rate<6 mL/min
Filter Bandwidth<15 nm
Linear Error (Na)<0.03 mmol/L
Linear Error (K)<0.005 mmol/L
Linear Error (Li)<0.021 mmol/L
Linear Error (Ca)<0.075 mmol/L
Linear Error (Ba)<0.066 mmol/L
Detection Limit (Na)<0.008 mmol/L
Detection Limit (K)<0.004 mmol/L
Detection Limit (Li)<0.015 mmol/L
Detection Limit (Ca)<0.050 mmol/L
Detection Limit (Ba)<0.066 mmol/L
PrintBuilt-in thermal printer
USB OutputHistorical records exportable via USB drive
Power220V±22V, 50Hz±1Hz, ≤50W
Dimensions460 mm × 325 mm × 450 mm
Weight~10 kg