Product Overview
The HM Instruments HM-ZLD is an integrated laboratory distillation apparatus with 3 independently controlled heating positions and 500 mL distillation flasks. Three positions with time-based endpoint control, built-in cooling, automatic cleaning and airtightness testing.
Select the required position count, endpoint control and cooling arrangement for your samples.
Key Features
- A 7-inch colour touchscreen provides independent settings and status monitoring for each heating position.
- Far-infrared ceramic heating bowls contact compatible round-bottom flasks, without an open flame.
- Anti-backflow protection and dry-heating protection are included; tubing and liquid levels must still be checked before use.
- Time settings cover 0–999 minutes, with up to 600 W of heating power per position.
- Time-based endpoint control stops the programmed heating cycle at the selected duration.
- A built-in cleaning pump flushes the distillate line without removing the flask body.
- Automatic airtightness checking helps inspect the assembled distillation path.
- Storage for up to 1,000 methods, including 18 commonly used national-standard method presets.
- The integrated chiller provides a 5–25°C controlled cooling-water circuit.
- Reverse blowing drains circulating water from the condenser tubes.
Applications
Designed for laboratory pretreatment procedures that require distillation, including environmental monitoring, water and wastewater analysis, inspection laboratories, research and teaching. Applications include distillation pretreatment for ammonia nitrogen, cyanide, volatile phenols and sulfides in water, with further soil, sediment and food method references.
Use the sample preparation, glassware and distillation procedure for the selected analyte. Analyse the collected distillate using the corresponding analytical method.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | HM-ZLD |
| Heating positions | 3; independently controlled |
| Display | 7-inch colour touchscreen |
| Heating method | Far-infrared ceramic heating bowls |
| Distillation flasks | 3 × 500 mL; spherical ground-joint round-bottom flasks |
| Receiving bottles | 3 × 250 mL |
| Heating temperature range | Room temperature to 400°C |
| Timing range | 0–999 min |
| Maximum heating power per position | 600 W |
| Endpoint control | Time |
| Automatic cleaning | Included |
| Manufacturer-stated distillation accuracy | 0.1 mL |
| Distillation rate | Up to 12 mL/min; depends on output power |
| Airtightness testing | Included |
| Cooling arrangement | Built-in water chiller with closed-loop control, 5–25°C |
| Rated input power | 2000 W |
| Power supply | 220 V, 50 Hz |
| Leakage-current protection | Included |
| Heating-up test condition | ≤6 min to boiling: 250 mL tap water in a 500 mL flask; ambient 25°C; 600 W at one position |
| Built-in chiller cooling capacity | 1.5 kW |
Configuration / Accessories
Principal items listed for this model are shown below; the final packing list controls the complete tubing and consumables quantities.
| Listed item | Quantity / scope |
|---|---|
| Main unit | 1 |
| Distillation flasks, 500 mL | 3 |
| Serpentine condensers | 3 |
| Receiving flasks, 250 mL | 3 |
| Glass elbow connectors / stoppers | 3 |
| Drip tips | 3 |
| Boiling stones | 1 pack |
| Silicone tubing and clamps | As listed in the model packing list |
| Manual, conformity certificate, warranty card and packing list | 1 each |
| Calibration weight | 1 × 100 g |
| Power cable | 1 |
The cooling-water chiller is built into this model. Export wooden packaging is optional. A suitable 16 A power socket must be provided by the user.
Related Models
| Model | Positions | Endpoint | Cooling | Automatic cleaning |
|---|---|---|---|---|
| HM-ZLA | 6 | Time | External supply | No |
| HM-ZLB | 6 | Volume / time | External supply | No |
| HM-ZLC | 6 | Volume / time | External supply | Yes |
| HM-ZLD | 3 | Time | Built-in | Yes |
| HM-ZLE | 3 | Volume / time | Built-in | Yes |
Operation and Support
Use the compatible flasks, assemble and secure the condensers and tubing, and verify that the paths are unobstructed. Establish cooling-water circulation before heating. Follow the method and instrument manual for liquid loading, parameter settings, collection and shutdown; keep the receiver clear of the delivery-tube walls and base.
For weighing-based operation, avoid touching or vibrating the receiver and weighing tray. Use the specified pure water in a chiller. Inspect tubing for wear, clean glassware after use and follow the manual for the model-specific cleaning procedure.
Product Enquiries
Contact our sales representative to confirm sample methods, flask configuration, cooling arrangements and supplied accessories.
Sales Contact: Grace
Email: graceliu@hmdzkj.cn
Tel / WhatsApp / WeChat: +86 17853698681
- Previous: Multi-function distillation apparatus
- Next: no more
Current
Location:
+86 17853698681
WhatsApp
Product Details
Related Products