Instrument Introduction

Environmental pollution has drawn close attention of governments and the public around the world, and the call for protecting ecological environment and atmospheric environment is rising day by day. Human beings cannot leave 5 minutes of air, 95% of which is distributed in the thickness of 12km on the earth surface. The main cause of atmospheric damage and pollution is the emission of CO2 and SO2. With the combustion of CO2 and SO2 source automatic fuel, the lower the sulfur content of gasoline, diesel, heavy oil, etc. used in vehicles, ships and aircrafts will greatly reduce the pollution to the atmosphere. Europe and China have developed a series of sulfur standards to limit production and emissions. SO2 will also cause catalyst poisoning in petrochemical industry and cause acid rain and other hazards in the atmosphere.

The X-ray fluorescence sulfur meter produced by our company is a special X-ray fluorescence analyzer developed and manufactured to meet the requirements of sulfur content detection in oil products. It adopts the principle of energy dispersion and the computer-based design of electromechanical integration, so the analysis is fast and accurate. Its repeatability and reproducibility comply with the relevant requirements of national standard GB/T17040 and petrochemical industry standard SH/T0742, and also fully comply with the more stringent American national standard ASTMD4294-03. It provides an important means for the detection of sulfur content in crude oil or petrochemical production process

Main purpose

Measure the total sulfur mass percentage content of crude oil, petroleum, heavy oil, diesel oil, kerosene, gasoline and naphtha;

Measure the total sulfur content in coal chemical products, such as primary benzene;

Measurement of total sulfur or sulfide content in other liquid samples;

Determination of carbon, total sulfur or SO3 content in fine powder samples, such as petroleum coke and modified asphalt.

Instrument features

Microcomputer design of instrument electromechanical integration, simple and beautiful;

Wide detection range, fast analysis speed and less standard sample consumption;

Relative comparison analysis method of fluorescent intensity ratio is adopted, temperature and atmospheric pressure are automatically corrected, and carbon/hydrogen ratio (C/H) can also be corrected;

Inch capacitor touch screen, high brightness, clear and visible in the sun, adjustable brightness; Clear and friendly software interface and simple operation;

Determine the working state and electrical parameters of the instrument through counting measurement and energy spectrum measurement;

Disposable Mylar membrane sample cup is used to avoid cross contamination; The sample cup can be made quickly and conveniently;

Place the sample platform on the slide rail platform and position it * *;

Large data storage of instrument, content analysis results and calibration curve parameters available at any time;

The sample cup shall be placed on the oil leak-proof part and moved to the measuring position only when the sample is analyzed;

Safety X-ray protection measures: strict protection measures shall be taken around the detection system of the instrument to prevent X-ray leakage and avoid X-ray ionizing radiation damage to individuals and groups.

Main technical indexes

Sulfur measurement range: 0.0017% - 5%;

Repeatability (r): ≤ 0.4347 X

X=average of two repeat test results);

Reproducibility (R): ≤ 1.9182 X

X=average of two single, independent test results);

Detection limit: 10ppm;

Oil quantity: 5ml ~ 6ml; Powder sample: 3 g

Measuring time: 60, 120, 180 seconds, arbitrarily set;

Single sample automatic measurement, give the average value and standard deviation after measurement;

Number of calibration curves: the instrument can access 10 calibration curves;

Operating conditions: temperature 10 ~ 30 ℃; Relative humidity: ≤ 85% (30 ℃);

Power supply: AC220V ± 20V, 50Hz/60Hz, rated power: 50W;