Instrument Introduction:
Karl Fischer titration (volumetric titration method) is a precision analytical instrument based on the classical Karl Fischer reaction principle, specifically designed for accurately determining the moisture content in samples. The volumetric method calculates the water content directly by the volume consumed by the titrant, with efficient operation and accurate and reliable results.
Detection Principle:
The Karl Fischer method is based on the quantitative reaction of I ₂, SO ₂, and water. The instrument uses the permanent stop titration method to indicate the endpoint, and the electrode monitors the sudden change in current during the titration process to accurately determine the reaction endpoint, thereby calculating the sample moisture content based on the consumed Karl Fischer test dose.
Applicable Standards:
The measurement accuracy of this Karl Fischer titration moisture meter (volumetric titration method) complies with the provisions of JJG 1154-2018 "Calibration Regulations for Karl Fischer titration Moisture Meters".
Application Scope:
This instrument is widely used in the fields of pharmaceuticals, chemicals, food, and petroleum, and is a key equipment for detecting moisture in quality control and scientific research.
Instrument Features:
1. The Android 10 operating system has multiple upload functions for WiFi and Ethernet cables, allowing for quick batch upload of data;
2. 7-inch high-definition Android touch screen, 1024 * 600 pixel clear and efficient UI interactive interface, enhancing operation and visual experience;
3. Using a precision servo system to drive a micro pump, achieving a minimum push of 1 μ L of extremely micro titrant;
4. Multiple polarization voltages are available, with polarization voltage error<± 1mV;
5. Wide current measurement range;
6. Moisture analysis error ≤ 7%, moisture analysis repeatability ≤ 3%;
7. Equipped with an automatic liquid inlet and outlet system, achieving zero reagent contact throughout the entire process for greater safety;
8. Equipped with a fully enclosed reaction tank and filtration system to avoid the risk of reagent volatilization;
9. The dynamic moisture determination titration algorithm can significantly improve titration efficiency while ensuring accuracy;
10. Built in detection method management, allowing for the creation of new methods or the editing and deletion of existing methods according to different needs;
11. Built in detection information management, which can be selected with one click when creating a new detection;
12. Having independent blank filling and titration calibration methods, the titration calibration results can be directly saved and validated for subsequent moisture determination;
13. Equipped with anti diffusion titration heads to avoid moisture measurement errors caused by the loss of titrant in idle tubes;
14. Configure a regulatory platform, and the detection results can be directly transmitted wirelessly to the platform;
15. Built in new generation high-speed thermal printer.
Technical Specifications:
1. Permanent stop polarization voltage: 30mV, 50mV, 100mV
2. Permanent stop voltage error: ± 1mV
3. Permanent stop current range: 0-200uA
4. Permanent stop current error: ± 1.0% FS
5. Repeatability of moisture analysis: ≤ 3%
6. Moisture analysis error: ≤ 7%
7. 10mL burette capacity accuracy: 1uL
8. Capacity error of 10mL burette: ± 10uL/10mL
9. 20mL burette capacity accuracy: 2uL
10. 20mL burette capacity error: ± 20uL/10mL
11. Data memory capacity: 100000-100000 records, searchable, and can be exported via USB
12. Power adapter: 12V 3A
13. Power consumption: 25W (standby power consumption: 10W)
14. Size: Host: 310x226x233 (400) (mm); Automatic liquid inlet and outlet system: 425x147x198 (mm)
15. Weight: Host: 3.7kg; Automatic liquid inlet and outlet system: 3.4kg