Selecting a portable 860 nm turbidity meter requires looking beyond headline NTU numbers to examine how the optical geometry handles both ultra-clear treated water and heavily turbid raw or process samples. In drinking water plants, environmental field surveys, wastewater treatment, and food or pharmaceutical manufacturing, turbidity measurements must remain stable even when water contains dissolved color or swings from under 1 NTU to several thousand NTU during storm runoff or sludge handling.

Within the handheld sensor series from HENG MEI Intelligent Manufacturing, two flagship 860 nm models address distinct operational priorities: the HM-SXT2 (0–4,000 NTU automatic scattering-plus-transmission turbidity meter) and the HM-SXTS (0–2,000 NTU scattering turbidity and suspended solids meter). Comparing their optical modes, standard calibration kits, unit options, and hardware durability ensures buyers pick the right instrument for their exact sampling conditions.

White and blue handheld 860 nm portable turbidity meter with 4.3-inch touchscreen and blue optical chamber cover

Why 860 nm Optics Are the Benchmark for Field Turbidity

Both HM-SXT2 and HM-SXTS use an imported 860 nm LED light source paired with a 10 × 10 mm large-area photocell. This optical design solves two persistent challenges in field turbidity testing:

  • Eliminating Dissolved Color Interference: Humic substances in river water, iron in groundwater, and organic pigments in beverage or industrial process streams absorb visible light. Operating at 860 nm in the near-infrared region avoids visible color absorption so readings reflect true suspended particulate scattering rather than sample tint, fulfilling HJ 1075-2019 and ISO 7027 requirements.
  • Zero Warm-Up and Low Detection Limit: Unlike tungsten lamps that require warm-up stabilization and periodic bulb replacement, the imported 860 nm LED turns on instantaneously with stable output. Combined with the 10 × 10 mm photocell, both instruments achieve 0.001 NTU resolution for trace-level drinking water verification.

Scattering-Only vs. Scattering + Transmission: HM-SXTS vs. HM-SXT2

While both instruments share the same ergonomic IP65 housing and 4.3-inch HD touchscreen, their optical measurement paths and parameter outputs serve different workflows. The table below compares their verified technical specifications and reference USD pricing.

Specification / FeatureHM-SXT2HM-SXTS
Measurement Principle90° Scattering + Transmission (automatic switching)90° Scattering
Light Source & WavelengthImported LED, 860 nmImported LED, 860 nm
Turbidity Range0–4,000 NTU0–2,000 NTU
Suspended Solids (SS)Single-parameter turbidityTurbidity + SS (Display = Turbidity × user factor)
Resolution0.001 NTU0.001 NTU; (0.001 × factor) mg/L
Indication Error±6%±6%
Repeatability≤ 0.5%≤ 0.5%
Zero Drift & Stability±0.5% FS / 30 min±0.5% FS / 30 min
Supported Display UnitsNTU (default), FAU, FNU, FTU, EBC, ASBCNTU (default), FAU, FNU, FTU, EBC, ASBC, mg/L
Calibration Standard Set8-bottle turbidity standard solution set7-bottle turbidity standard solution set
Applicable StandardsHJ 1075-2019, ISO 7027, JJG 880-2006, GB 5749, CJ 3020, GB/T 14848HJ 1075-2019, ISO 7027, JJG 880-2006, GB 5749, CJ 3020, GB/T 14848
Ingress ProtectionIP65; chamber resists 0.5 mL liquid ingressIP65; chamber resists 0.5 mL liquid ingress
Display & MemoryAndroid OS, 4.3-inch HD touchscreen; 16 GB (> 10,000 records)Android OS, 4.3-inch HD touchscreen; 16 GB (> 10,000 records)
Battery & Charging8000 mAh lithium; USB-C 5V/2.1A (BC2.1)8000 mAh lithium; USB-C 5V/2.1A (BC2.1)
Dimensions & Weight246 × 59.4 × 84 mm; 0.59 kg246 × 59.4 × 84 mm; 0.59 kg
Reference SKU Price (USD)$830$880

For buyers comparing the full turbidity lineup, HENG MEI also provides entry-level colorimetric and benchtop alternatives within the same product group. The table below summarizes all six configurations and their reference USD pricing so procurement teams can match accuracy, range, and budget across field and laboratory roles.

ModelForm Factor & Optical MethodMeasurement RangeReference SKU Price (USD)
HM-NTUHandheld transmitted-light turbidity meter0.5–300 NTU$330
HM-SNTHandheld transmitted-light turbidity + SS meter0.5–300 NTU; 1–600 mg/L SS$350
HM-SXT1Handheld 860 nm 90° scattering turbidity meter0–2,000 NTU$680
HM-SXT2Handheld 860 nm scattering + transmission (auto-switch)0–4,000 NTU$830
HM-SXTSHandheld 860 nm scattering turbidity + SS meter0–2,000 NTU + SS (factor)$880
TUR-4000Benchtop high-precision scattering + transmission meter0–4,000 NTU$1,100

When to Choose HM-SXT2 ($830 USD)

At high particle concentrations, pure 90° scattering suffers from multiple-scattering attenuation, which narrows the linear upper range. The HM-SXT2 overcomes this by pairing 90° scattering (for low-to-medium turbidity) with transmitted-light attenuation (for high turbidity) and switching between the two modes automatically. This extends the measurement range to 0–4,000 NTU without sacrificing 0.001 NTU low-end resolution, making HM-SXT2 ideal for raw surface-water intakes during flood events, sedimentation-basin profiling, industrial slurry-adjacent process checks, and high-range regulatory inspections.

When to Choose HM-SXTS ($880 USD)

If your maximum turbidity stays within 0–2,000 NTU and your team also needs suspended solids readings in mg/L without running gravimetric filtration in a lab, the HM-SXTS delivers dual-parameter output. Under stable water-source and particle-size conditions, operators enter an empirical conversion coefficient (e.g., initial 1 NTU ≈ 1 mg/L) so the meter displays both NTU and mg/L simultaneously.

Portable 860 nm scattering turbidity and suspended solids meter with ergonomic white and blue housing

Ruggedness, Power, and Data Workflow for Field Teams

Field turbidity meters often fail not because of optical drift, but because of water ingress, dead batteries, or fragile glass-cell alignment. Both HM-SXT2 and HM-SXTS address these operational risks directly:

  • IP65 Enclosure & Chamber Sealing: The housing is rated IP65 against dust and water jets, while the optical detection chamber itself resists up to 0.5 mL of internal liquid ingress—protecting the electronics if a sample bottle is overfilled or condensation forms.
  • 8000 mAh Battery & Universal USB-C Charging: An internal 8000 mAh lithium battery with smart charge management supports USB-C 5V/2.1A (BC2.1 protocol), allowing crews to recharge from standard third-party phone chargers, power banks, or continuous plug-in operation.
  • 16 GB Storage & Flexible Export: With 16 GB of memory (> 10,000 test records), Wi-Fi, Bluetooth, and direct USB-to-PC batch upload, field teams can archive measurements with zero manual transcription.
  • Cross-Marked 25 × 60 mm Sample Bottles: Each unit ships with five 25 × 60 mm colorimetric bottles marked with an alignment cross so operators insert the bottle in the exact same orientation every time, minimizing glass-wall variance.

Standard Kits and Optional Field Accessories

Both HM-SXT2 and HM-SXTS arrive in a 315 × 290 × 110 mm portable accessory case containing:

  • 1 main turbidity meter host
  • 5 colorimetric bottles (25 × 60 mm with alignment cross)
  • 1 full turbidity standard solution set (8 bottles for HM-SXT2; 7 bottles for HM-SXTS)
  • 1 charger (5V/2A, 10 W) and 1 Type-C 5A data cable (1 m)
  • 2 large nitrile gloves, 1 lens-cleaning cloth, 1 instruction manual, 1 certificate of conformity, and 1 warranty card

Three optional accessories are available for specialized field deployments: a portable Bluetooth printer, thermal printing paper (φ 57 × 30 mm) for immediate on-site compliance slips, and a 220V portable power station (500 W continuous power, 360 Wh capacity, with car charger) for multi-day remote sampling expeditions.

Packing List / OptionHM-SXT2HM-SXTS
Instrument Host (IP65, 860 nm LED)1 unit1 unit
Colorimetric Bottles (25 × 60 mm with alignment cross)5 pcs5 pcs
Turbidity Standard Solution Set1 set (8 bottles/set)1 set (7 bottles/set)
Charger (5V/2A, 10 W) & Type-C 5A Cable (1 m)1 each1 each
Nitrile Gloves (Large) & Lens-Cleaning Cloth2 gloves + 1 cloth2 gloves + 1 cloth
Instruction Manual, Certificate, Warranty Card1 set1 set
Portable Accessory Box (315 × 290 × 110 mm)1 box1 box
Optional AccessoriesBluetooth printer, thermal paper, 220V power stationBluetooth printer, thermal paper, 220V power station

Procurement Specification Checklist

When preparing a tender or purchasing specification for portable 860 nm turbidity meters, verify five criteria before ordering:

  1. Upper Turbidity Ceiling: Confirm whether raw-water storm spikes or industrial slurries exceed 2,000 NTU (requiring HM-SXT2's 0–4,000 NTU scattering-plus-transmission range).
  2. Suspended Solids Output: Determine whether field crews need converted mg/L suspended solids readings directly on screen (selecting HM-SXTS).
  3. Standards Traceability: Verify that ISO 7027, HJ 1075-2019, JJG 880-2006, GB 5749, CJ 3020, and GB/T 14848 match your laboratory and regulatory reporting requirements.
  4. Reporting Units: Confirm whether beverage or brewing workflows require EBC or ASBC units alongside NTU, FNU, FAU, and FTU.
  5. Field Printing & Off-Grid Power: Decide whether to add the optional Bluetooth thermal printer and 220V portable power station to the initial purchase.

Comparing Operating Endurance and Field Ergonomics

Both HM-SXT2 and HM-SXTS weigh 0.59 kg and measure 246 × 59.4 × 84 mm, balancing one-handed portability with a 4.3-inch HD color touchscreen that remains easy to read outdoors. Their 8000 mAh lithium battery charges over standard USB-C 5V/2.1A (BC2.1 protocol), allowing field teams to top up from vehicle adapters or commercial power banks during multi-day watershed surveys. Combined with 16 GB of internal memory (> 10,000 test records), Wi-Fi, Bluetooth, and USB-to-PC batch transfer, operators can document raw intake spikes, filter-run profiles, and effluent compliance without carrying paper clipboards.

Application Selection Summary

  • Water Utilities & Tap Water Plants: HM-SXT2 covers raw intake spikes up to 4,000 NTU and filtered effluent down to 0.001 NTU under GB 5749 and HJ 1075-2019.
  • Wastewater Treatment Plants: HM-SXTS tracks aeration and effluent turbidity plus converted suspended solids (mg/L) in a single pass.
  • Food, Beverage & Brewing: Both models support EBC and ASBC units natively alongside NTU and FTU.
  • Environmental & Emergency Screening: IP65 protection, 8000 mAh battery, and included multi-point standard solutions enable rapid deployment during pollution events.

Frequently Asked Questions

What is the difference between 90° scattering and scattering-plus-transmission?

90° scattering provides high sensitivity at low and medium turbidity (0–2,000 NTU on HM-SXTS). Adding a transmitted-light detector (as on HM-SXT2) lets the meter automatically switch to transmission mode at high particle densities, extending the linear range up to 4,000 NTU.

Do HM-SXT2 and HM-SXTS meet ISO 7027 and HJ 1075-2019?

Yes. Both models use an 860 nm LED light source and 90° optical geometry aligned with ISO 7027, HJ 1075-2019, JJG 880-2006, GB 5749, CJ 3020, and GB/T 14848.

Can I switch display units without re-calibrating?

Yes. While NTU is the default unit, operators can switch display units among FAU, FNU, FTU, EBC, ASBC (plus mg/L on HM-SXTS) directly in the Android interface.

What happens if a sample spills inside the optical chamber?

The detection chamber is engineered to resist up to 0.5 mL of liquid ingress, and the outer housing meets IP65 protection. Wipe the chamber dry with a clean lint-free cloth before resuming measurement.

Are calibration standards included in the base price?

Yes. HM-SXT2 ($830 USD) includes an 8-bottle turbidity standard solution set, and HM-SXTS ($880 USD) includes a 7-bottle turbidity standard solution set.

Requesting a Quotation from HENG MEI Intelligent Manufacturing

Shandong Hengmei Electronic Technology Co., Ltd. (brand: HENG MEI Intelligent Manufacturing) supplies HM-SXT2 and HM-SXTS portable 860 nm turbidity meters with bilingual English/Simplified Chinese software and factory calibration kits. To request a formal quotation, specify whether you need the 0–4,000 NTU dual-mode HM-SXT2 or the 0–2,000 NTU turbidity-plus-SS HM-SXTS, along with any optional Bluetooth printer or power accessories.

Contact: Arthur, Sales Contact, Arthur@hmdzkj.cn, +86 18353666151 (Tel / WhatsApp / WeChat).