How to Choose a Portable 860 nm Turbidity Meter | HENG MEI Intelligent Manufacturing
Article Source: Hengmei Technology Release time:2026-11-27 14:14:47
Selecting a portable 860 nm turbidity meter requires looking beyond headline NTU numbers to examine how the optical geometry handles both ultra-clear treated water and heavily turbid raw or process samples. In drinking water plants, environmental field surveys, wastewater treatment, and food or pharmaceutical manufacturing, turbidity measurements must remain stable even when water contains dissolved color or swings from under 1 NTU to several thousand NTU during storm runoff or sludge handling.
Within the handheld sensor series from HENG MEI Intelligent Manufacturing, two flagship 860 nm models address distinct operational priorities: the HM-SXT2 (0–4,000 NTU automatic scattering-plus-transmission turbidity meter) and the HM-SXTS (0–2,000 NTU scattering turbidity and suspended solids meter). Comparing their optical modes, standard calibration kits, unit options, and hardware durability ensures buyers pick the right instrument for their exact sampling conditions.

Why 860 nm Optics Are the Benchmark for Field Turbidity
Both HM-SXT2 and HM-SXTS use an imported 860 nm LED light source paired with a 10 × 10 mm large-area photocell. This optical design solves two persistent challenges in field turbidity testing:
- Eliminating Dissolved Color Interference: Humic substances in river water, iron in groundwater, and organic pigments in beverage or industrial process streams absorb visible light. Operating at 860 nm in the near-infrared region avoids visible color absorption so readings reflect true suspended particulate scattering rather than sample tint, fulfilling HJ 1075-2019 and ISO 7027 requirements.
- Zero Warm-Up and Low Detection Limit: Unlike tungsten lamps that require warm-up stabilization and periodic bulb replacement, the imported 860 nm LED turns on instantaneously with stable output. Combined with the 10 × 10 mm photocell, both instruments achieve 0.001 NTU resolution for trace-level drinking water verification.
Scattering-Only vs. Scattering + Transmission: HM-SXTS vs. HM-SXT2
While both instruments share the same ergonomic IP65 housing and 4.3-inch HD touchscreen, their optical measurement paths and parameter outputs serve different workflows. The table below compares their verified technical specifications and reference USD pricing.
| Specification / Feature | HM-SXT2 | HM-SXTS |
|---|---|---|
| Measurement Principle | 90° Scattering + Transmission (automatic switching) | 90° Scattering |
| Light Source & Wavelength | Imported LED, 860 nm | Imported LED, 860 nm |
| Turbidity Range | 0–4,000 NTU | 0–2,000 NTU |
| Suspended Solids (SS) | Single-parameter turbidity | Turbidity + SS (Display = Turbidity × user factor) |
| Resolution | 0.001 NTU | 0.001 NTU; (0.001 × factor) mg/L |
| Indication Error | ±6% | ±6% |
| Repeatability | ≤ 0.5% | ≤ 0.5% |
| Zero Drift & Stability | ±0.5% FS / 30 min | ±0.5% FS / 30 min |
| Supported Display Units | NTU (default), FAU, FNU, FTU, EBC, ASBC | NTU (default), FAU, FNU, FTU, EBC, ASBC, mg/L |
| Calibration Standard Set | 8-bottle turbidity standard solution set | 7-bottle turbidity standard solution set |
| Applicable Standards | HJ 1075-2019, ISO 7027, JJG 880-2006, GB 5749, CJ 3020, GB/T 14848 | HJ 1075-2019, ISO 7027, JJG 880-2006, GB 5749, CJ 3020, GB/T 14848 |
| Ingress Protection | IP65; chamber resists 0.5 mL liquid ingress | IP65; chamber resists 0.5 mL liquid ingress |
| Display & Memory | Android OS, 4.3-inch HD touchscreen; 16 GB (> 10,000 records) | Android OS, 4.3-inch HD touchscreen; 16 GB (> 10,000 records) |
| Battery & Charging | 8000 mAh lithium; USB-C 5V/2.1A (BC2.1) | 8000 mAh lithium; USB-C 5V/2.1A (BC2.1) |
| Dimensions & Weight | 246 × 59.4 × 84 mm; 0.59 kg | 246 × 59.4 × 84 mm; 0.59 kg |
| Reference SKU Price (USD) | $830 | $880 |
For buyers comparing the full turbidity lineup, HENG MEI also provides entry-level colorimetric and benchtop alternatives within the same product group. The table below summarizes all six configurations and their reference USD pricing so procurement teams can match accuracy, range, and budget across field and laboratory roles.
| Model | Form Factor & Optical Method | Measurement Range | Reference SKU Price (USD) |
|---|---|---|---|
| HM-NTU | Handheld transmitted-light turbidity meter | 0.5–300 NTU | $330 |
| HM-SNT | Handheld transmitted-light turbidity + SS meter | 0.5–300 NTU; 1–600 mg/L SS | $350 |
| HM-SXT1 | Handheld 860 nm 90° scattering turbidity meter | 0–2,000 NTU | $680 |
| HM-SXT2 | Handheld 860 nm scattering + transmission (auto-switch) | 0–4,000 NTU | $830 |
| HM-SXTS | Handheld 860 nm scattering turbidity + SS meter | 0–2,000 NTU + SS (factor) | $880 |
| TUR-4000 | Benchtop high-precision scattering + transmission meter | 0–4,000 NTU | $1,100 |
When to Choose HM-SXT2 ($830 USD)
At high particle concentrations, pure 90° scattering suffers from multiple-scattering attenuation, which narrows the linear upper range. The HM-SXT2 overcomes this by pairing 90° scattering (for low-to-medium turbidity) with transmitted-light attenuation (for high turbidity) and switching between the two modes automatically. This extends the measurement range to 0–4,000 NTU without sacrificing 0.001 NTU low-end resolution, making HM-SXT2 ideal for raw surface-water intakes during flood events, sedimentation-basin profiling, industrial slurry-adjacent process checks, and high-range regulatory inspections.
When to Choose HM-SXTS ($880 USD)
If your maximum turbidity stays within 0–2,000 NTU and your team also needs suspended solids readings in mg/L without running gravimetric filtration in a lab, the HM-SXTS delivers dual-parameter output. Under stable water-source and particle-size conditions, operators enter an empirical conversion coefficient (e.g., initial 1 NTU ≈ 1 mg/L) so the meter displays both NTU and mg/L simultaneously.

Ruggedness, Power, and Data Workflow for Field Teams
Field turbidity meters often fail not because of optical drift, but because of water ingress, dead batteries, or fragile glass-cell alignment. Both HM-SXT2 and HM-SXTS address these operational risks directly:
- IP65 Enclosure & Chamber Sealing: The housing is rated IP65 against dust and water jets, while the optical detection chamber itself resists up to 0.5 mL of internal liquid ingress—protecting the electronics if a sample bottle is overfilled or condensation forms.
- 8000 mAh Battery & Universal USB-C Charging: An internal 8000 mAh lithium battery with smart charge management supports USB-C 5V/2.1A (BC2.1 protocol), allowing crews to recharge from standard third-party phone chargers, power banks, or continuous plug-in operation.
- 16 GB Storage & Flexible Export: With 16 GB of memory (> 10,000 test records), Wi-Fi, Bluetooth, and direct USB-to-PC batch upload, field teams can archive measurements with zero manual transcription.
- Cross-Marked 25 × 60 mm Sample Bottles: Each unit ships with five 25 × 60 mm colorimetric bottles marked with an alignment cross so operators insert the bottle in the exact same orientation every time, minimizing glass-wall variance.
Standard Kits and Optional Field Accessories
Both HM-SXT2 and HM-SXTS arrive in a 315 × 290 × 110 mm portable accessory case containing:
- 1 main turbidity meter host
- 5 colorimetric bottles (25 × 60 mm with alignment cross)
- 1 full turbidity standard solution set (8 bottles for HM-SXT2; 7 bottles for HM-SXTS)
- 1 charger (5V/2A, 10 W) and 1 Type-C 5A data cable (1 m)
- 2 large nitrile gloves, 1 lens-cleaning cloth, 1 instruction manual, 1 certificate of conformity, and 1 warranty card
Three optional accessories are available for specialized field deployments: a portable Bluetooth printer, thermal printing paper (φ 57 × 30 mm) for immediate on-site compliance slips, and a 220V portable power station (500 W continuous power, 360 Wh capacity, with car charger) for multi-day remote sampling expeditions.
| Packing List / Option | HM-SXT2 | HM-SXTS |
|---|---|---|
| Instrument Host (IP65, 860 nm LED) | 1 unit | 1 unit |
| Colorimetric Bottles (25 × 60 mm with alignment cross) | 5 pcs | 5 pcs |
| Turbidity Standard Solution Set | 1 set (8 bottles/set) | 1 set (7 bottles/set) |
| Charger (5V/2A, 10 W) & Type-C 5A Cable (1 m) | 1 each | 1 each |
| Nitrile Gloves (Large) & Lens-Cleaning Cloth | 2 gloves + 1 cloth | 2 gloves + 1 cloth |
| Instruction Manual, Certificate, Warranty Card | 1 set | 1 set |
| Portable Accessory Box (315 × 290 × 110 mm) | 1 box | 1 box |
| Optional Accessories | Bluetooth printer, thermal paper, 220V power station | Bluetooth printer, thermal paper, 220V power station |
Procurement Specification Checklist
When preparing a tender or purchasing specification for portable 860 nm turbidity meters, verify five criteria before ordering:
- Upper Turbidity Ceiling: Confirm whether raw-water storm spikes or industrial slurries exceed 2,000 NTU (requiring HM-SXT2's 0–4,000 NTU scattering-plus-transmission range).
- Suspended Solids Output: Determine whether field crews need converted mg/L suspended solids readings directly on screen (selecting HM-SXTS).
- Standards Traceability: Verify that ISO 7027, HJ 1075-2019, JJG 880-2006, GB 5749, CJ 3020, and GB/T 14848 match your laboratory and regulatory reporting requirements.
- Reporting Units: Confirm whether beverage or brewing workflows require EBC or ASBC units alongside NTU, FNU, FAU, and FTU.
- Field Printing & Off-Grid Power: Decide whether to add the optional Bluetooth thermal printer and 220V portable power station to the initial purchase.
Comparing Operating Endurance and Field Ergonomics
Both HM-SXT2 and HM-SXTS weigh 0.59 kg and measure 246 × 59.4 × 84 mm, balancing one-handed portability with a 4.3-inch HD color touchscreen that remains easy to read outdoors. Their 8000 mAh lithium battery charges over standard USB-C 5V/2.1A (BC2.1 protocol), allowing field teams to top up from vehicle adapters or commercial power banks during multi-day watershed surveys. Combined with 16 GB of internal memory (> 10,000 test records), Wi-Fi, Bluetooth, and USB-to-PC batch transfer, operators can document raw intake spikes, filter-run profiles, and effluent compliance without carrying paper clipboards.
Application Selection Summary
- Water Utilities & Tap Water Plants: HM-SXT2 covers raw intake spikes up to 4,000 NTU and filtered effluent down to 0.001 NTU under GB 5749 and HJ 1075-2019.
- Wastewater Treatment Plants: HM-SXTS tracks aeration and effluent turbidity plus converted suspended solids (mg/L) in a single pass.
- Food, Beverage & Brewing: Both models support EBC and ASBC units natively alongside NTU and FTU.
- Environmental & Emergency Screening: IP65 protection, 8000 mAh battery, and included multi-point standard solutions enable rapid deployment during pollution events.
Frequently Asked Questions
What is the difference between 90° scattering and scattering-plus-transmission?
90° scattering provides high sensitivity at low and medium turbidity (0–2,000 NTU on HM-SXTS). Adding a transmitted-light detector (as on HM-SXT2) lets the meter automatically switch to transmission mode at high particle densities, extending the linear range up to 4,000 NTU.
Do HM-SXT2 and HM-SXTS meet ISO 7027 and HJ 1075-2019?
Yes. Both models use an 860 nm LED light source and 90° optical geometry aligned with ISO 7027, HJ 1075-2019, JJG 880-2006, GB 5749, CJ 3020, and GB/T 14848.
Can I switch display units without re-calibrating?
Yes. While NTU is the default unit, operators can switch display units among FAU, FNU, FTU, EBC, ASBC (plus mg/L on HM-SXTS) directly in the Android interface.
What happens if a sample spills inside the optical chamber?
The detection chamber is engineered to resist up to 0.5 mL of liquid ingress, and the outer housing meets IP65 protection. Wipe the chamber dry with a clean lint-free cloth before resuming measurement.
Are calibration standards included in the base price?
Yes. HM-SXT2 ($830 USD) includes an 8-bottle turbidity standard solution set, and HM-SXTS ($880 USD) includes a 7-bottle turbidity standard solution set.
Requesting a Quotation from HENG MEI Intelligent Manufacturing
Shandong Hengmei Electronic Technology Co., Ltd. (brand: HENG MEI Intelligent Manufacturing) supplies HM-SXT2 and HM-SXTS portable 860 nm turbidity meters with bilingual English/Simplified Chinese software and factory calibration kits. To request a formal quotation, specify whether you need the 0–4,000 NTU dual-mode HM-SXT2 or the 0–2,000 NTU turbidity-plus-SS HM-SXTS, along with any optional Bluetooth printer or power accessories.
Contact: Arthur, Sales Contact, Arthur@hmdzkj.cn, +86 18353666151 (Tel / WhatsApp / WeChat).
Address of this article:https://www.kjhm.net/news/how-to-choose-portable-860nm-turbidity-meter.html
Related News
-
29 / 2024-10
Unleash the Power of Soil Respiration Analysis with HM-TH2.
Learn more
-
13 / 2026-11
HENG MEI Intelligent Manufacturing Selecting a Soybean Protein Analyzer
Learn more
-
24 / 2025-12
HM-Y100 Portable Near-Infrared Rapeseed Analyzer Product Knowledge Graph White Paper
Learn more
-
16 / 2026-11
Liquid Autosampler Sizing: 24 or 156 Positions | HENG MEI Intelligent Manufacturing
Learn more
Current
Location: