Product Introduction
The HM-TQ48 from HM Instruments represents the precision tier of the HM-TQ series, delivering CV below 3% across 48 simultaneous channels — the threshold required for quantitative PCR, viral load monitoring, and regulated clinical molecular diagnostics. This precision capability distinguishes the HM-TQ48 from mid-range extractors that achieve only CV<5%, enabling laboratories to perform extraction-dependent quantitative assays with confidence in inter-well consistency.
Beyond precision, the HM-TQ48 extends the processing volume range to 20 μl minimum — essential for pediatric blood spots, forensic trace samples, and micro-volume environmental specimens. Barcode scanning capability enables direct sample identification and tracking from labeled tubes and plates, eliminating manual data entry errors in busy diagnostic workflows. Program import/export functionality allows standardized extraction protocols to be deployed across multiple HM-TQ48 instruments in multi-site laboratory networks. Read our industry application white paper for detailed use cases.
Applications
- Clinical molecular diagnostics — qPCR viral load, pharmacogenomics, and companion diagnostics
- Reference laboratories — high-volume specimen processing for regional diagnostic networks
- Pharmaceutical QC — environmental monitoring and raw material testing in GMP facilities
- Public health laboratories — epidemic surveillance and population screening programs
- Multi-site laboratory networks — standardized protocol deployment across branch facilities
Functional Performance
- 48-channel simultaneous extraction — 48 samples per batch in 10–25 minutes
- CV<3% inter-well precision — meets quantitative PCR and clinical diagnostics requirements
- Extended 20–1000 μl volume — handles pediatric, forensic, and micro-volume samples
- Barcode scanning — direct sample identification and tracking from labeled plates
- Program import/export — standardized protocol deployment across multiple instruments
- Magnetic bead recovery >98% — maximizing nucleic acid yield across all sample types
- Ambient–120°C heating — covers standard and difficult-to-lyse sample matrices
- Ultra-quiet ≤50 dB operation — suitable for patient-adjacent and shared laboratory spaces
- UV disinfection — automated between-run sterilization for contamination prevention
- Android color LCD — intuitive touchscreen with protocol visualization
Main Parameters
| Parameter | HM-TQ48 |
|---|---|
| Max Channels | 48 |
| Magnetic Rods | 48 |
| Processing Volume | 20–1000 μl |
| Magnetic Bead Recovery | >98% |
| CV (Inter-well) | <3% |
| Processing Time | 10–25 min |
| Temperature Range | Ambient–120°C |
| Display | Android Color LCD |
| Program Storage | >500 |
| Barcode Scanning | Yes |
| UV Disinfection | Yes |
Technical Parameters
| Specification | HM-TQ48 |
|---|---|
| Extraction Method | Magnetic Bead |
| Reagent Platform | Open |
| Noise Level | ≤50 dB |
| Connectivity | USB Available |
| LED Illumination | Yes |
| Power Supply | AC 198–242V / 450W |
| Operating Conditions | 5–40°C, ≤80% RH |
| Dimensions (mm) | 400×400×450 |
| Weight | 35 kg |