Organic fertilizer testing equipment

Organic fertilizer testing equipment

Product Number:

HM-FC

Product Difference:

Can detect nitrogen, phosphorus, potassium, organic matter, pH, trace elements such as calcium, magnesium, sulfur, iron, manganese, boron and heavy metals such as lead, chromium, cadmium, mercury, arsenic, nickel and aluminum in chemical fertilizers and organic fertilizers.

/skin/Product Details



Fertilizer nutrient detector FC.jpg



Features:

★ "Chassis/agent integrated aluminum alloy chassis" professional design, easy to carry, durable, with complete sets of accessories and finished medicines.

★Microcomputer control, digital circuit, program design, LCD display, AC and DC dual-use, can be used for field flow testing.

★Resolution: 0.001, touch button, built-in new generation thermal printer, can print test results.

★It can detect the available nitrogen, available phosphorus, effective potassium, total nitrogen, total phosphorus, total potassium, organic matter, pH, calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, molybdenum and other trace elements and various heavy metals such as lead, chromium, cadmium, mercury, arsenic, nickel, aluminum, fluorine, titanium, selenium and so on in chemical fertilizers and organic fertilizers (including foliar fertilizers, water-soluble fertilizers, spray fertilizers, etc.).

★It adopts high-brightness LED light source and double-wheel filter processing technology to ensure the stability of the light source wavelength. Silicon semiconductor is used as the signal receiving system, and the life span is up to 100,000 hours. The light source is stable, reproducible and accurate.

★The colorimetric tank adopts a single-channel design, without mechanical displacement and wear, and the optical path test positioning is accurate to ensure the accuracy of the measurement results.

★It adopts high-precision filter technology and independent patented analysis methods to ensure that the test results are better than the national standard requirements.

★The fertilizer print result is a percentage content, and the test error is less than 0.5%.


Multiple functions and complete test items:

Fertilizer nutrients: ● Nitrogen, phosphorus, and potassium in single-element fertilizers; ● Ammonium nitrogen, nitrate nitrogen, phosphorus, potassium, and biuret in compound (mixed) fertilizers and urea; ● Quick-acting nitrogen, quick-acting phosphorus, quick-acting potassium, total nitrogen, total phosphorus, total potassium, organic matter, and various humic acids in organic fertilizers (foliar fertilizers). It can be expanded to detect trace elements such as calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, molybdenum, and various heavy metals (lead, chromium, cadmium, mercury, arsenic, nickel, aluminum, fluorine, titanium, and selenium).


Instrument technical indicators:

1. Power supply: AC 220±22V DC 12V+5V (vehicle power supply or built-in lithium battery)

2. Power: ≤5W

3. Range and resolution: 0.001-9999

4 Repeatability error: ≤0.02% (0.0002, potassium dichromate solution)

5. Instrument stability: drift within one hour is less than 0.3% (0.003, transmittance measurement). After the instrument is turned on and preheated for 5 minutes, the displayed digital display has no drift within 30 minutes (transmittance measurement), and the digital drift within one hour does not exceed 0.3% (0.003, transmittance measurement); within three hours, the digital drift does not exceed 0.7% (0.007, transmittance measurement), 0.002 (absorbance measurement).

6. Linear error: ≤0.1% (0.001, copper sulfate detection)

7. Sensitivity: red light ≥4.5 × 10-5 blue light ≥3.17 × 10-3 green light ≥2.35 × 10-3 orange light ≥2.13 × 10-3

8. Wavelength range: red light: 680 ± 2nm; blue light: 420 ± 2nm; green light: 510 ± 2nm; orange light: 590 ± 4nm

9. PH value (acidity): (1) Test range: 1 to 14 (2) Accuracy: 0.01 (3) Error: ±0.1

10. Simultaneous, rapid and accurate detection of nutrients such as nitrogen (N), phosphorus (P), potassium (K) in fertilizers

11. Test speed: ≤50 minutes to test one fertilizer sample (N, P, K) (including pre-processing time, no accessories required by the user)

12. ≤2 hours to test 5 fertilizer samples at the same time (including pre-processing time)

13. Data printing: built-in new one-button thermal printer


Test speed:

8 samples can be tested simultaneously;

Test one compound fertilizer sample (N, P, K) ≤50 minutes; 20 minutes more time for each additional fertilizer sample.

Test one organic fertilizer sample (N, P, K, organic matter) ≤1.5 hours; 30 minutes more time for each additional sample.


Test error

The single error of fertilizer is ≤0.5%, and the total error of nitrogen, phosphorus and potassium is ≤1%.


Instrument features:

Full functions: Comprehensive test items at home and abroad (all kinds of agents can be purchased).

Completely equipped, the instrument integrates medicine, equipment and instrumentation, is easy to carry, and is equivalent to a small laboratory. Users only need to provide distilled water to complete all operations within the required time.

Reliable performance: The working stability is more than 8 times better than the national standard JJG179-90 index, and the repeatability reaches the index level of the grating spectrophotometer.