Product Introduction:
BOD Biochemical Oxygen Demand Meter is based on the national standard "HJ505-2009" 5-day culture method, simulating the biodegradation process of organic matter in nature, and using a simple, safe and reliable mercury-free pressure difference sensing method to measure BOD in water; fully intelligent design, leading R&D process and design and manufacturing, the experimental process does not require laboratory personnel on duty; It is suitable for biochemical oxygen demand determination in sewage discharge enterprises, environmental monitoring, sewage treatment plants, third-party testing institutions, scientific research, universities and other fields.
Technical parameters:
Measurement item: BOD
Measurement range: 0-4000mg/L (direct measurement)
Resolution: 0.01mg/L
Sampling points: ≤60/cycle
Measurement principle: mercury-free differential pressure method;
Measurement accuracy: ±8%
Data storage: 10 years of test data can be stored
Stirring: program control, magnetic stirring
Measurement cycle: 1 day--30 days
Number of measurements: 6 independent groups of tests
Cultivation bottle volume: 580ml
Cultivation temperature: 20±1℃
Battery life: ≥2 years
Power configuration: AC220V±10%/50-60HZ
Product size: 275x185x305mm
Product features:
1. Six samples can be measured at the same time;
2. Six independent test terminals, new measurement groups can be added at any time during the test process;
3. Directly read the BOD concentration value without calculation;
4. Mercury-free differential pressure design, high accuracy, no need for conversion, and ensure the safety and health of the experimenters;
5. There is no pipeline design in the experimental stage to avoid pipeline aging, leakage and other disadvantages;
6. The measurement range can be selected. When the water sample concentration is lower than 4000g/L, no dilution is required;
7. The analyzer automatically records the measurement data. 60 sampling points can be selected in one test cycle, and the test data is more accurate;
8. The culture cycle is adjustable and can be selected according to needs;
9. The measurement process is completed automatically without the need for special personnel on duty;
10. The large-size LCD display is intuitive and clear, and the project selection is convenient;
11. The test terminal comes with a large-capacity battery with a battery life of more than 2 years. The test process is not affected by short-term power outages in the external environment.